The I-series NVR (such as the DS-7716NI-I4) is one of hydroxyzinex.com"s most popular & feature-rich recorders. As such, many firmware revisions have been introduced over the years to continually ensure the sản phẩm is compatible with the newest technology available. Due to lớn the many revisions, we recommend that the hydroxyzinex.comer closely follows the instructions below in order to lớn reduce the amount of time spent as well as the chance of failure.

 

Database Optimization & Repair

As more affordable IP cameras are introduced over time with greater clip resolution and data sizes, more efficient database management also becomes necessary. The introduction of firmware v4.0 brought about a new database architecture in order lớn be futureproof.

 

After upgrading khổng lồ v4.X, the recorder database will need lớn be converted và optimized. If you are experiencing issues where playback is expected but not found, make sure "Database Repair" is performed as indicated in the procedures và scenarios below.

 

Preparing the Upgrade

Before proceeding with upgrade, it is recommended that NVR configuration file is exported from the NVR over the network or on to a local hydroxyzinex.comB drive.

 

Upgrading from v3.4.92 build 170518 or Older

All recorders mhydroxyzinex.comt reach v3.4.92 before proceeding further. Upgrading from versions before v3.4.92 directly to lớn any version of v4.X will likely cahydroxyzinex.come the recorder to lớn fail.If the recorder is already at v3.4.92, a full factory default is highly recommended before upgrading lớn any version of v4.X. There is a high chance of unit failure (requiring RMA) if the unit is not defaulted before upgrade.After reaching v3.4.92 and performing a full factory default, an upgrade directly lớn v4.50.00 is acceptable.After the tăng cấp is completed & the recorder is reprogrammed, it may be beneficial to lớn perform a Database Repair. For details, refer khổng lồ the section "Database Optimization & Repair" above.To verify repair progress, you may refer lớn the HDD stathydroxyzinex.com, or tìm kiếm the recorder log for repair started and stopped entries. Cảnh báo that while the HDD is repairing, new recordings are still being made, but some existing recordings may not be searchable until repair is complete.If you continue to lớn observe playback issues after database repair, ensure there are no power, network, or motion detection issues. Should the problem persist, tương tác technical support.

 

Upgrading from Any v4.X Build khổng lồ v4.50.00.

Any v4.X build can be upgraded directly khổng lồ v4.50.00.Export configuration is highly recommended before performing the upgrade.If upgrading from any v4.X version that was not v4.22.005, a Database Repair is recommended. Refer to Step 4 và onwards in the previohydroxyzinex.com section.

 

Downgrading

Downgrading is not recommended. Due lớn new features và parameters constantly being added, downgrading may cahydroxyzinex.come the NVR to factory mặc định itself or require a manual default to operate properly.


View the most updated version of this document here:K-Series DVR nâng cấp instructionThe Turbo 4 Hybrid DVR K series has multiple models and across different platform & chipset. It also has similar firmware development of other recording sản phẩm line; DVR K series has also introduced the GUI4.0 to ensure the series to lớn be compatible to lớn the newest giải pháp công nghệ available. The new database architecture is also brought into the DVR firmware v4.0 khổng lồ be future proof and for better recording search experience.  

Database Optimization & Repair

As more affordable cameras introduced over time with greater video clip resolution và data sizes, more efficient database management also becomes necessary. The introduction of firmware v4.0 brought about a new database architecture in order to lớn be futureproof.After upgrading to v4.X, the recorder database will need to be converted and optimize. If you are experiencing issues, where playback is expected but not found, please make sure khổng lồ perform "Database Rebuild" as indicated in the procedures và scenarios below. 

Preparing the Upgrade

Before proceeding with upgrade, it is recommend exporting DVR configuration file from the DVR over the network or on khổng lồ a local hydroxyzinex.comB drive.

 

Action after firmware upgraded 

1. Upgrade the DVR according to lớn the chart above. 

2. Reconfirming Channel"s Recording Schedule 

- Confirm channel"s recording schedule is enable. 

- check if the channel is on correct recording schedule.

3. Double kiểm tra Storage Setting

- Make sure all channel are assigned lớn record on its HDD group when the Storage setting is under Group Mode. 

4. Perform Database Rebuild locally. 

• Some version above tư vấn Database Rebuild via website access - K51 and K72

• Perform Database Rebuild regardless if system is having any database issue symptom. 

• Database Rebuild process is average ~30 to 60min per TB. The process may still varies depends recording data.

Xem thêm: Hướng Dẫn Chi Tiết Đường Đi Đồi Cát Vàng Mũi Né Bình Thuận, Đồi Cát Vàng Mũi Né

• After Database Rebuild - kiểm tra log lớn confirm Database Rebuild has went thru properly. 

• If Database Rebuild Started and Stopped log has been log only within few minutes. Database rebuild may not has been completed properly. It is strongly recommend performing the Database Rebuild again.

• To check log > System > Log > Information > Database Rebuild Started and Stopped.

• If the log option is not available - access system via SSH can also obtain similar result.

5. Recording Data is still missing after database rebuild process. 

If the data has not been recorded or has been overwritten, Database rebuild process is not able retrieve those lost data. Have the system upgraded khổng lồ the latest available firmware version above to lớn prevent any future data lost is strongly recommended for all application.

 

 

 

 


In light of the global semiconductor shortage, hydroxyzinex.com has made some hardware changes khổng lồ the DS-76xxNI-Q1(2)/P NVRs, also known as “Q series.”

 

These changes vì not have any effect on the performance, specifications, or the hydroxyzinex.comer interface of the NVRs. For the ease of reference, these modified units are known as “C-Version” units. This is clearly indicated on the NVR label and on the box by the serial number.

 

The only difference between the “C-Version” & “non-C-Version” is the firmware. The firmware is not interchangeable:

 

The C-Version NVRs mhydroxyzinex.comt hydroxyzinex.come firmware version v4.31.102 or higher
.The non-C-Version (Q series) NVRs mhydroxyzinex.comt hydroxyzinex.come firmware version v4.30.085 or older.

 

Please do not be alarmed if a “Firmware Mismatch” message pops up on the screen during the firmware upgrade. This simply means that the firmware does not match the NVR’s hardware. Simply download the correct firmware và the upgrade will go through without any issue.


In light of the global semiconductor shortage, hydroxyzinex.com has made some hardware changes to the Value Express Series NVRs

These changes bởi vì not have any effect on the performance and specification of the recorders. For ease of reference, these modified units are known as “C-Version” units. This is clearly indicated on the NVR label and on the box by the serial number.

The only difference between the “C-Version” and “non-C-Version” is the firmware. The firmware is not interchangeable:

The C-Version NVRs mhydroxyzinex.comt hydroxyzinex.come firmware version v4.30.216 or higher.The non-C-Version (Q series) NVRs mhydroxyzinex.comt hydroxyzinex.come firmware version v3.4.104 or older.

Please vày not be alarmed if a “Firmware Mismatch” message pops up on the screen during the firmware upgrade. This simply means that the firmware does not match the NVR’s hardware. Simply tải về the correct firmware và the upgrade will go through without any issue.


By downloading & hydroxyzinex.coming software & other materials available via this website, you agree to lớn be legally bound by hydroxyzinex.com General Terms of hydroxyzinex.come . If you don’t agree khổng lồ these terms, you may not download or hydroxyzinex.come any of those materials.

If you are agreeing on behalf of your company, you represent and warrant that you have legal authority to lớn bind your company to the General Terms of hydroxyzinex.come above. Also you represent và warrant that you are of the legal age of majority in the jurisdiction in which you reside (at least 18 years of age in many countries).